Is your order time-sensitive? Send us an email or call us to see which suppliers are experiencing material shortages or delayed shipping times.

UST/AST Tank Management System

*Image is a representation of this item. Actual item may vary.*
Hover over image to zoom

Pneumercator TMS2000 UST/AST Tank Management System

With EPA-Compliant In-Tank Leak Detection

Ships From Manufacturer

Select Model & Quantity:

Model # Description Price Qty
TMS2000-21-00-0 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 115/230 VAC $2,871.38
TMS2000-21-00-1 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 8-16 VDC $3,412.50
TMS2000-21-00-2 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 16-60 VDC $3,412.50
TMS2000-22-00-0 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 4 Encl., 115/230 VAC $3,149.25
TMS2000-22-00-1 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 4 Encl., 8-16 VDC $3,690.38
TMS2000-22-00-2 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 4 Encl., 16-60 VDC $3,690.38
TMS2000-23-00-0 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 4X Encl., 115/230 VAC $3,534.38
TMS2000-23-00-1 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 4X Encl., 8-16 VDC $4,075.50
TMS2000-23-00-2 With Display, No Printer, Max 2 Tanks, 8 sensors, NEMA 4X Encl., 16-60 VDC $4,075.50
TMS2000-31-00-0 With Display/Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 115/230 VAC $3,622.13
TMS2000-31-00-1 With Display/Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 8-16 VDC $4,163.25
TMS2000-31-00-2 With Display/Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 16-60 VDC $4,163.25
TMS2000-41-00-0 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 115/230 VAC $3,929.25
TMS2000-41-00-1 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 8-16 VDC $4,470.38
TMS2000-41-00-2 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 12 Encl., 16-60 VDC $4,470.38
TMS2000-42-00-0 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 4 Encl., 115/230 VAC $4,207.13
TMS2000-42-00-1 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 4 Encl., 8-16 VDC $4,748.25
TMS2000-42-00-2 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 4 Encl., 16-60 VDC $4,748.25
TMS2000-43-00-0 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 4X Encl., 115/230 VAC $4,592.25
TMS2000-43-00-1 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 4X Encl., 8-16 VDC $5,133.38
TMS2000-43-00-2 With Display/Autowinder Printer, Max 2 Tanks, 8 sensors, NEMA 4X Encl., 16-60 VDC $5,133.38
Contact Us
Pneumercator - TMS2000 - UST/AST Tank Management System
  • Extremely flexible, modular system architecture. Completely field configurable and upgradeable.
  • Support for up to 2 precision, dual float magnetostrictive level probes.
  • Provisions for monitoring up to 8 intrinsically safe discrete sensor inputs, including discriminating and non-discriminating interstitial, overfill, and secondary leak containment sensors. Sensor wiring fault detection feature ensures correct installation when used with Pneumercator "F" series fault output discrete sensors.
  • Basic configuration includes 2 relays and 2 contact closure inputs. Optionally expandable to a total of 10 relays and 10 contact closure inputs OR 18 relays.
  • Optionally expandable to 6 or 12 channel analog outputs.
  • Third party certified for 0.1 and 0.2 gph in-tank leak detection in tanks up to 75,000 gallons.
  • Optional internal impact printer for automatic or on-demand reports. Outdoor printer option available.
  • Remotely monitor and program via an included RS-232 serial port, from a central location via optional, secured, internal modem, or from a LAN/WAN via optional, secured, internal network interface card. RS-485 port included for connection to Pneumercator "smart" peripherals, such as remote display and annunciator panels.
  • Log reports include: Automatic shift inventory, unsupervised deliveries, bulk sales, alarms, leak test, water removal, product ordering, and theft logging.
  • NEMA 4/4X enclosure options available for harsh or outdoor environments.

Features

  • 0.2 gph monthly testing.
  • 0.1 gph precision test.
  • 0.2 gph quick test in as little as 2 hours.
  • Perform 0.1 gph or 0.2 gph tests with as little as 20% of tank capacity.
  • Magnetostrictive level probe and intrinsically safe (IS) discrete sensor capacities; 2 probes with 8 leak sensors.
  • Fault detection capable leak sensor inputs using Pneumercator "F" series discrete sensors.
  • RS-232 serial port standard. Optional secured, internal modem, Fax/modem, 10/100 network interface card, or Modbus RTU. RS-485 peripheral bus standard.
  • 2 fully programmable 10 amp 120 VAC relay output contacts and 2 dry contact inputs standard. Optional card provides additional 4 relay contacts, and 4 dry contact inputs, OR 8 relay contacts, and 8 dry contact inputs, OR 16 relay outputs.
  • Optional card provides 6 or 12 analog output channels.
  • Real-time clock and log memory with battery back-up; Configuration data maintained in EEPROM.
  • Superbright, sunlight-readable LED display with discrete LED annunciators for 5 alarm conditions; Leak, Setpoint 1, Setpoint 2, Setpoint 3 and Water.
  • Automatic logging of shift inventory, unsupervised deliveries, bulk sales, alarms, leak test, water removal, product ordering, and thefts.
  • Access real-time logged and configuration data via RS-232 or modem port using Windows 2000 through Windows 10 compatible TMSCOMM software.
  • Automatic and manual hardcopy reports via optional internal printer. Outdoor printer option available.
  • Volumetric computations for steel and fiberglass tanks, including manifolded tanks and irregular geometries.
  • System configuration can be performed at the site, or remotely via the serial, modem communications port, or network interface.
  • "Black box" configuration available for ultra low-cost applications where serial, modem communications, or LAN/WAN are used for collecting acquisition and log data; remote sites or SIR.
  • Locking NEMA 12 enclosure standard, optional NEMA 4 or 4X available.
  • Back-up generator and oil/water separator applications supported.
  • UL approved, file #E139464; CSA approval pending.
  • 110/220 VAC operation. DC Input options available.