Single-Tank Gauging System

*Image is a representation of this item. Actual item may vary.*
Hover over image to zoom

Pneumercator TMS1000N Single-Tank Gauging System

With Temperature Control and Secondary Containment Leak Detection for Water Management Applications

Ships From Manufacturer

Select Model & Quantity:

Model # Description Price Qty
TMS1000N-23-00-0 With Display, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC $2,003.63
TMS1000N-23-30-0 With Display/Internal Ethernet Network Interface Card, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC $2,929.88
TMS1000N-23-40-0 With Display/Internal 14400 Baud Modem, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC $2,544.75
TMS1000N-23-50-0 With Display/Internal ModBus RS-485 RTU Interface Card, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC $3,134.63
Contact Us
Pneumercator - TMS1000N - Single-Tank Gauging System
Console

  • Dimensions (W x H x D): 10.2" x 6.3" x 4.0 (259 mm x 160 mm x 102 mm)
  • Weight: 6 lb (2.7 kg)
  • Operating Temperature: -40 °F to 160 °F (-40 °C to 70 °C)
  • Humidity: 95% Non-condensing
  • Enclosure Rating: NEMA 4X (IP56) (Epoxy Powder-Coated Alloy Enclosure)
  • Power Requirements: 115/230 VAC 15% Switchable, 50-60 Hz, 10 W Max.
  • Memory: Configuration / Setup Data & EEPROM, 50 year data retention, no batteries. Log Reports and Real-Time Clock & Lithium Battery-Backed RAM, 5-10 year data retention.
  • Audible Alarm: 100 db
  • Display: 9-Character, Super Bright LED Data Display, Readable from 25" (7.6 m). Ultra-High Intensity Alarm LEDS, Visible from 75" (22.9 m).
  • Display Data: Gross Volume, Net Volume (Temperature Corrected), % Volume, Ullage, Water Level, Water Temperature
  • Communications: RS-232 Included Standard, RJ-13 Jack. Internal, Secured Modem, Network Interface or ModBus Optional.
  • Probe / Sensor Capacities: 1 Magnetostrictive Probe MP55x or MP56x Series. 2 Leak/Point-Level Sensors, Supervised Wiring Ready.
  • I / O, Non-Haz.: Standard: 4 Relays, 1 Form A, Rated 5A @120/240 VAC, w/ 2 Opto-Isolated Inputs. No Expansion.
  • Alarms: High-High, High, Low, Temperature and Secondary Containment Leak
  • Relay Controls: Water - Critical High, High-High, High, Low, Low-Low, Critical Low. Temperature - High-High, High, Low, Low-Low. Secondary Containment Leak Sensor Input. Non-Hazardous Contact Closure Input

Probe

  • Technology: Magnetostrictive, Single-Float, w/ reflection resolution doubling
  • Accuracy (Minimum): MP55xS: MP56x: Product Level: 0.01" (0.25 mm) Product Level: 0.01" (0.25 mm). Temperature: 0.1 °F (0.06 °C) Temperature: 0.1 °F (0.06 °C).
  • Materials: Shaft: 316 SS Rigid, PVDF Flexible. Float: 316 SS or Buna-N.
  • Mounting: Inventory Only: 2" minimum riser (4" preferred), direct bushing/flange, sanitary mount
  • Temperature Sensing: Single sensor standard. Five sensor array available
  • Location Approval: Ordinary
  • Operating Temperature: -40 °F to 175 °F (-40 °C to 80 °C)
  • Operating Pressure: 150 PSIG (1034 kPa) 316SS, 50 PSIG (345 kPa) PVDF
  • Field Wiring: 22AWG, 3-Conductor w/ shield and drain wire. Belden 6501FE or equiv., maximum length 50" (15.2 m).
  • Models: MP55xS Series rigid SS max. length 24" (7.3 m). MP56x Series flex. PVDF max. length 70" (21.3 m).

Sensors

  • ES825-300FL Electronic, Non-Discriminating - Containment, Manway and Piping Sumps, Dry Annular
  • LS600LD Float, Containment, Manway and Piping Sumps
  • LS600xx Multi-Float, High / Low Level and Pump Control
  • RSU800 Float, Wet Annular / Reservoir
  • LS610 Float, Dry Annular

Most sensors are available with Fault-Detect Supervised sensor and wiring option. Add FL Suffix to Model Number

Overall Rating

|

0 Review(s)


No reviews yet!

Be the first to add a review.

*Reviews are subject to approval