*Image is a representation of this item. Actual item may vary.*
Hover over image to zoom
Pneumercator TMS1000N Single-Tank Gauging System
With Temperature Control and Secondary Containment Leak Detection for Water Management Applications
Ships From Manufacturer
Select Model & Quantity:
Model # | Description | Price | Qty |
---|---|---|---|
TMS1000N-23-00-0 | With Display, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC | $2,003.63 | |
TMS1000N-23-30-0 | With Display/Internal Ethernet Network Interface Card, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC | $2,929.88 | |
TMS1000N-23-40-0 | With Display/Internal 14400 Baud Modem, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC | $2,544.75 | |
TMS1000N-23-50-0 | With Display/Internal ModBus RS-485 RTU Interface Card, Max 1 DEF Tank, 2 sensors, NEMA 4X Encl., 115/230 VAC | $3,134.63 |
Pneumercator - TMS1000N - Single-Tank Gauging System
Console- Dimensions (W x H x D): 10.2" x 6.3" x 4.0 (259 mm x 160 mm x 102 mm)
- Weight: 6 lb (2.7 kg)
- Operating Temperature: -40 °F to 160 °F (-40 °C to 70 °C)
- Humidity: 95% Non-condensing
- Enclosure Rating: NEMA 4X (IP56) (Epoxy Powder-Coated Alloy Enclosure)
- Power Requirements: 115/230 VAC 15% Switchable, 50-60 Hz, 10 W Max.
- Memory: Configuration / Setup Data & EEPROM, 50 year data retention, no batteries. Log Reports and Real-Time Clock & Lithium Battery-Backed RAM, 5-10 year data retention.
- Audible Alarm: 100 db
- Display: 9-Character, Super Bright LED Data Display, Readable from 25" (7.6 m). Ultra-High Intensity Alarm LEDS, Visible from 75" (22.9 m).
- Display Data: Gross Volume, Net Volume (Temperature Corrected), % Volume, Ullage, Water Level, Water Temperature
- Communications: RS-232 Included Standard, RJ-13 Jack. Internal, Secured Modem, Network Interface or ModBus Optional.
- Probe / Sensor Capacities: 1 Magnetostrictive Probe MP55x or MP56x Series. 2 Leak/Point-Level Sensors, Supervised Wiring Ready.
- I / O, Non-Haz.: Standard: 4 Relays, 1 Form A, Rated 5A @120/240 VAC, w/ 2 Opto-Isolated Inputs. No Expansion.
- Alarms: High-High, High, Low, Temperature and Secondary Containment Leak
- Relay Controls: Water - Critical High, High-High, High, Low, Low-Low, Critical Low. Temperature - High-High, High, Low, Low-Low. Secondary Containment Leak Sensor Input. Non-Hazardous Contact Closure Input
Probe
- Technology: Magnetostrictive, Single-Float, w/ reflection resolution doubling
- Accuracy (Minimum): MP55xS: MP56x: Product Level: 0.01" (0.25 mm) Product Level: 0.01" (0.25 mm). Temperature: 0.1 °F (0.06 °C) Temperature: 0.1 °F (0.06 °C).
- Materials: Shaft: 316 SS Rigid, PVDF Flexible. Float: 316 SS or Buna-N.
- Mounting: Inventory Only: 2" minimum riser (4" preferred), direct bushing/flange, sanitary mount
- Temperature Sensing: Single sensor standard. Five sensor array available
- Location Approval: Ordinary
- Operating Temperature: -40 °F to 175 °F (-40 °C to 80 °C)
- Operating Pressure: 150 PSIG (1034 kPa) 316SS, 50 PSIG (345 kPa) PVDF
- Field Wiring: 22AWG, 3-Conductor w/ shield and drain wire. Belden 6501FE or equiv., maximum length 50" (15.2 m).
- Models: MP55xS Series rigid SS max. length 24" (7.3 m). MP56x Series flex. PVDF max. length 70" (21.3 m).
Sensors
- ES825-300FL Electronic, Non-Discriminating - Containment, Manway and Piping Sumps, Dry Annular
- LS600LD Float, Containment, Manway and Piping Sumps
- LS600xx Multi-Float, High / Low Level and Pump Control
- RSU800 Float, Wet Annular / Reservoir
- LS610 Float, Dry Annular
Most sensors are available with Fault-Detect Supervised sensor and wiring option. Add FL Suffix to Model Number
No reviews yet!
Be the first to add a review.
*Reviews are subject to approval