*Image is a representation of this item. Actual item may vary.*
Hover over image to zoom
Pneumercator LC1000-A Series LC1000-A Audible/Visual Alarm Console
with Test/Reset
Ships From Manufacturer
Select Model & Quantity:
Model # | Description | Price | Qty |
---|---|---|---|
LC1000-A-03-10-0 | with Test/Reset, Single Sensor Input, Single Relay Output, NEMA 4X Enclosure, 95-250VAC | $823.88 | |
LC1000-A-03-20-0 | with Test/Reset, Two Sensor Input, Two Relay Output, NEMA 4X Enclosure, 95-250VAC | $1,014.00 | |
LC1000-A-03-30-0 | with Test/Reset, Three Sensor Input, Three Relay Output, NEMA 4X Enclosure, 95-250VAC | $1,477.13 | |
LC1000-A-03-40-0 | with Test/Reset, Four Sensor Input, Four Relay Output, NEMA 4X Enclosure, 95-250VAC | $1,662.38 | |
LC1000-A-05-10-0 | with Test/Reset, Single Sensor Input, Single Relay Output, NEMA 4X 316SS Enclosure, 95-250VAC | $1,413.75 | |
LC1000-A-05-20-0 | with Test/Reset, Two Sensor Input, Two Relay Output, NEMA 4X 316SS Enclosure, 95-250VAC | $1,603.88 | |
LC1000-A-05-30-0 | with Test/Reset, Three Sensor Input, Three Relay Output, NEMA 4X 316SS Enclosure, 95-250VAC | $2,325.38 | |
LC1000-A-05-40-0 | with Test/Reset, Four Sensor Input, Four Relay Output, NEMA 4X 316SS Enclosure, 95-250VAC | $2,510.63 |
Pneumercator - LC1000-A Series - LC1000-A Audible/Visual Alarm Console
The LC1000-A series is a cost-effective solution for use as a secondary containment leak alarm console, single or multi-point level alarm or control, or simply as a remote audible/visual alarm indicator. The console is available in one, two, three or four sensor input configurations, with a corresponding number of super-bright visual LED indicators and Form C relay contact outputs. Front panel, industrial quality pushbuttons are provided to test system operation and acknowledge alarm conditions, and a front panel LED indicates input power status. The LC1000-A comes standard with a NEMA 4X(IP56) weatherproof and corrosionproof FRP enclosure, stainless steel or NEMA 7 explosionproof available as options. Please consult factory.Specifications
- Dimensions (W x H x D): 1, 2-Input: 7.3" x 9.5" x 5.9" (186 mm x 242 mm x 149 mm). 3, 4-Input: 11.4" x 9.3" x 6.4" (291 mm x 236 mm x 162 mm).
- Weight: 1, 2-Input: 4.7 lb (2.2 kg). 3, 4-Input: 7.4 lb (3.4 kg).
- Operating Temperature: -40 °F to 160 °F (-40 °C to 70 °C)
- Humidity: 95% Non-condensing
- Enclosure Rating: NEMA 4X (IP56)
- Power Requirements: Universal 95-250 VAC, 50-60 Hz, 10 W Max.
- Audible Alarm: 103 dB w/Louvered Volume Control
- Visual Alarm Indicators: Superbright Red LEDs, Wide Viewing Angle
- Power Indicator: Superbright Green LED
- Controls: TEST, RESET
- Relay Outputs: Form C, Rated: 10 A @120 VAC; 6A @240 VAC, One Relay Output per Sensor Input
- Sensor Capacities: 1, 2, 3 or 4 Normally Open or Normally Closed Sensors
- Standard Programming*: NORMALLY OPEN/CLOSED and HORN ENABLE/DISABLE per Sensor Input. NORMAL or FAILSAFE Relay Mode and FRONT PANEL ACKNOWLEDGE per Relay Output. Horn AUTO SILENCE OFF, 1-9 MINUTES. *Consult factory for special applications and custom programming.
Sensors
- LS600-LDBN Float-Type Leak Sensor, Containment, Manway and Piping Sumps, Dispenser Pan
- LS600-LDSS Float, Containment, Manway and Piping Sumps for Solvent and Chemical Applications
- LS600 Standard Multi-Float, High / Low Level and Pump Control
- LS600F4 Heavy Duty, Bulk Tank Multi-Float, High / Low Level
- LS600M Sub-Base Generator Mini Series Multi-Float, High / Low Level
- LS600W Oil/Water Separator Multi-Float, High / Low Level
- LS600X Fully Submergible Multi-Float, High / Low Level and Pump Control
- RSU800/810 Float, Tank Wet Annular / Reservoir
- RSU810 Float, Collar Wet Annular / Reservoir
- LS610 Float, Dry Annular
Certifications/Approvals
- FM/cFM Approved, File # FM16US0281X/FM16CA0143X
- Third-Party Approved, EPA-Compliant for Secondary Leak Detection