Is your order time-sensitive? Send us an email or call us to see which suppliers are experiencing material shortages or delayed shipping times.

LCR-II Register

*Image is a representation of this item. Actual item may vary.*
Hover over image to zoom

Liquid Controls LCR2-E Series LCR-II Register

E36 Series; Division 2 Enclosure, External Pulser

Ships From Manufacturer

Select Model & Quantity:

Model # Description Price Qty
LCR2-E-GG E36 Series; Division 2 Enclosure, External Pulser, Gallons, Gross $3,117.14
LCR2-E-GN E36 Series; Division 2 Enclosure, External Pulser, Gallons, Net $3,117.14
LCR2-E-LG E36 Series; Division 2 Enclosure, External Pulser, Liters, Gross $3,117.14
LCR2-E-LN E36 Series; Division 2 Enclosure, External Pulser, Liters, Net $3,117.14

Add Optional Accessories

Model # Description Price Qty
E25352 Mulitplexer - For Connecting to Dual Meter Systems. $927.73
82506 Printer Sharing Device - Enables Sharing 1 Printer with Up to 6 Registers. $680.73
E49004 Slip Ticket Printer - Cables Not Included $878.33
E49005 Roll Printer - Cables Not Included $898.09
E49102 Thermal Roll Printer - Cables Not Included $898.09
E49007 Roll Printer without Take Up Reel - 3 ft. RS 232 Data Cable, 25 Pin Male/25 Pin Female $937.61
E49008 Roll Printer with Take Up Reel E49006 - 3 ft. RS 232 Data Cable, 25 Pin Male/25 Pin Female $1,467.18
82502 Cable Kit - 40 ft., Single Meter LCR-II, Power Cable, Data Cable, and 2 ft. Printer Power Supply $651.09
82526 Cable Kit - 40 ft., Dual Meter LCR-II, Power Cables, Data Cables, and 6 ft. Printer Power Supply $1,141.14
Contact Us
Liquid Controls - LCR2-E Series - LCR-II Register

Liquid Controls produces among the most reliable and accurate metering systems available, worldwide. For truck-mounted or fixed-site custody transfer applications requiring Weights & Measures-approved accuracy, LC products deliver consistent, error-free, dependable service. Liquid Controls family of LectroCount electronic registers provide:

  • Improved efficiency relative to mechanical systems
  • Electronic temperature compensation
  • Weights & Measures approvals
  • Ruggedness and reliability
  • Simplicity of operation
  • Compatibility with mobile computing solutions such as the DMS i1000
  • Muti-point calibration to improve the accuracy over a wide flow range
  • Electronic Temperature Volume Compensation (ETVC) to reduce lost volume
  • Increased security
  • Future expansion and modularity with RS232/485 communcation
  • Greater control and accuracy of the delivery system through use of two stage valves, optical air eliminators with a LectroCount register as a central control unit
  • Lower total cost of ownership through fewer moving parts, solid state electronics and longer MTBF (Mean Time Between Failure).

REPEATABLILITY: Capable of .03% of reading over entire range.
LINEARITY: Capable of ±0.10% or better over a 5:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.10% or better over a 10:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.15% or better over a 40:1 range from maximum nominal meter capacity.


Due to the capabilities of multi-point calibration for meters equipped with LectroCount™Electronic Registration, superior accuracy (linearity) can be provided as indicated above.

NOTE: Accuracy obtainable when all variables remain constant. Reading/ measurements must be equal to a minimum of one minute of flow at selected rate(s). All accuracy statements based on metering Stoddard Solvent, approximate viscosity 1 CPS. On higher viscosity products, the average deviation in accuracy will be even less.

Power Requirements:
LectroCount® LCR-II: +9 - 28 VDC
LectroCount® LCR 600: +9 - 28VDC


Environmental:
Enclosure: Class 1, Division 2, Group C&D design, Nema 4X
Operating Temp Range: -40° to 158°F (-40° to 70°C)


Approvals:
US Weights & Measures: LCR-II and LCR 600
Measurement Canada: LCR-II, LCR 600


Communications:
RS232/485
Printer: Epson, Okidata and Blaster Models


Electrical:
Power: +9 to 28VDC, 3A maximum (including solenoid valves)


Inputs:
Temperature input: 4-Wire Platinum RTD
Pulse Inputs: +5 to 28 volt peak to peak, open collector, single channel or quadrature


Outputs:
Control Valve (2): Open drain transistor for 2 stage valve control, 1A Max. per channel
Auxiliary (2): Open drain transistor for general purpose auxiliary control. Aux(1) 1A Max, Aux(2) 150mA Max
Scaled Pulse Output: Open drain output, 1 A Max.